Hi,
I ordered a HM-18 labeled device from DSD TECH. This one reponds with 'OK+RENEW' and 'OK+RESET'.
With 'NO Security' options I get again disconnect
Security settings works fine
OK+RENEW OK+RESET OK+Set:2 OK+Set:123456
But again disconnect
What is the issue, do you see any hints?
THX
Cheers
I ordered a HM-18 labeled device from DSD TECH. This one reponds with 'OK+RENEW' and 'OK+RESET'.
With 'NO Security' options I get again disconnect
Code:
> bScanning for LE devices - 10 seconds..Enable LE scan< HCI OGF=08 OCF=0C 0000 01 0C 20 02 01 01> Event 0E = 01 0C 20 00 0000 04 0E 04 01 0C 20 00> Event 3E = 02 01 00 00 CC 35 9C 93 72 84... 0000 04 3E 28 02 01 00 00 CC - 35 9C 93 72 84 1C 02 01 0010 06 09 FF 48 4D 84 72 93 - 9C 35 CC 07 16 00 B0 00 0020 00 00 00 03 02 E0 FF 02 - 0A 05 D2Disable LE scan< HCI OGF=08 OCF=0C 0000 01 0C 20 02 00 001 FOUND 84:72:93:9C:35:CC - Fixed Flags = 06 Manuf specific = 48 4D 84 72 93 9C 35 CC Service Data = 00 B0 00 00 00 00 Some 2-byte UUIDs FFE0 Tx Power Level = 05 Known device 1001 LE 84:72:93:9C:35:CCFound 0 unknown devices> cAVAILABLE DEVICES 1001 - LE 84:72:93:9C:35:CCInput node (x=cancel)? 1001BONDING (save pairing info) 0 = Do not bond - OK for most servers 1 = New bond 2 = Re-Pair with a previously bonded deviceBond (x=cancel)? 0PAIRING and SECURITY 0 = Do not pair - OK for most servers 1 = Pair - Just Works 2 = Pair - Fixed Passkey 3 = Pair - Random PasskeyInput pair option (x=cancel)? 0CONNECTION COMPLETE TIME After connecting, some LE servers need more time to complete the process or they will disconnect. Zero may work, otherwise find the shortest time that will prevent disconnection. Current value=750 (x=cancel to keep) Default value=750Time in ms (x=cancel)? 750< HCI OGF=08 OCF=0A 0000 01 0A 20 01 00SEND LE connect to LE 84:72:93:9C:35:CC Set [10].. board address reversed CC..84< HCI OGF=08 OCF=0D 0000 01 0D 20 19 60 00 60 00 - 00 00 CC 35 9C 93 72 84 0010 00 18 00 28 00 00 00 11 - 01 00 00 00 00> Event 0E = 01 0C 20 00 0000 04 0E 04 01 0C 20 00> Event 0E = 01 0A 20 0C 0000 04 0E 04 01 0A 20 0C> Event 0F = 00 01 0D 20 0000 04 0F 04 00 01 0D 20> Event 3E = 01 00 40 00 00 00 CC 35 9C 93... 0000 04 3E 13 01 00 40 00 00 - 00 CC 35 9C 93 72 84 27 0010 00 00 00 11 01 00Connect OK as LE clientHandle = 0040Set larger data length Set [4][5] handle 40 00< HCI OGF=08 OCF=22 0000 01 22 20 06 40 00 FB 00 - 00 08Set MTU Set [1][2] handle 40 00< CHANNEL 0004 Opcode = 02 0000 02 40 00 07 00 03 00 04 - 00 02 F7 00> Event 0E = 01 22 20 00 40 00 0000 04 0E 06 01 22 20 00 40 - 00> Event 13 = 01 40 00 01 00 0000 04 13 05 01 40 00 01 00 LE 84:72:93:9C:35:CC has disconnected> Event 05 = 00 40 00 3E 0000 04 05 04 00 40 00 3E>OK+RENEW OK+RESET OK+Set:2 OK+Set:123456
But again disconnect
Code:
> cAVAILABLE DEVICES 1001 - LE 84:72:93:9C:35:CCInput node (x=cancel)? 1001BONDING (save pairing info) 0 = Do not bond - OK for most servers 1 = New bond 2 = Re-Pair with a previously bonded deviceBond (x=cancel)? 0PAIRING and SECURITY 0 = Do not pair - OK for most servers 1 = Pair - Just Works 2 = Pair - Fixed Passkey 3 = Pair - Random PasskeyInput pair option (x=cancel)? 2PASSKEY chosen by 0 = This local device 1 = Remote serverEnter 0/1 (x=cancel)? 1Fixed 6-digit passkey (x=cancel)? 123456CONNECTION COMPLETE TIME After connecting, some LE servers need more time to complete the process or they will disconnect. Zero may work, otherwise find the shortest time that will prevent disconnection. Current value=750 (x=cancel to keep) Default value=750Time in ms (x=cancel)? 2000PAIRING COMPLETE TIMEThis might include the time to enter a passkeyor pairing will fail with a timeoutTime in ms (x=cancel)? 2000< HCI OGF=08 OCF=0A 0000 01 0A 20 01 00SEND LE connect to LE 84:72:93:9C:35:CC Set [10].. board address reversed CC..84< HCI OGF=08 OCF=0D 0000 01 0D 20 19 60 00 60 00 - 00 00 CC 35 9C 93 72 84 0010 00 18 00 28 00 00 00 11 - 01 00 00 00 00> Event 0E = 01 0A 20 0C 0000 04 0E 04 01 0A 20 0C> Event 0F = 00 01 0D 20 0000 04 0F 04 00 01 0D 20> Event 3E = 01 00 40 00 00 00 CC 35 9C 93... 0000 04 3E 13 01 00 40 00 00 - 00 CC 35 9C 93 72 84 27 0010 00 00 00 11 01 00Connect OK as LE clientHandle = 0040Set larger data length Set [4][5] handle 40 00< HCI OGF=08 OCF=22 0000 01 22 20 06 40 00 FB 00 - 00 08Set MTU Set [1][2] handle 40 00< CHANNEL 0004 Opcode = 02 0000 02 40 00 07 00 03 00 04 - 00 02 F7 00> Event 0E = 01 22 20 00 40 00 0000 04 0E 06 01 22 20 00 40 - 00> Event 13 = 01 40 00 01 00 0000 04 13 05 01 40 00 01 00 LE 84:72:93:9C:35:CC has disconnected> Event 05 = 00 40 00 3E 0000 04 05 04 00 40 00 3EPair LE 84:72:93:9C:35:CC - not connected as LE server>THX
Cheers